H03VV-F
PVC insulated and sheathed light fine wired cable
HRN EN 50525-2-11 - EN 50525-2-11 - IEC 60227-5

VDE-certified cable cable conforms to Low voltage directive max. permitted conductor temperature min. installation temperature flame retardant acc. IEC 60332-1
CONSTRUCTION
Conductor    bare copper conductor, fine wired stranded, class 5 acc. to EN 60228

Insulation   PVC compound TI1 acc. to EN 50363-3

Sheath   PVC compound TM2 for flexible cables acc. to EN 50363-4-1
APPLICATION

Flexible cable for dry areas, used for purposes requiring special flexibility in conditions free of any mechanical stresses. Permitted frequent bending and twisting. Specially suitable for application in small devices with low mechanical loads and for connection of light household devices such as kitchen appliances, desk lamps, ceiling lamps, vacuum cleaners, office machines, radios etc., as long as the cable is adapted to essential specifications of the device. These cables must not be used for cooking and heating devices. They are not suitable for outdoor use or for industrial (except for sewing-machines and similar) and agricultural machines.
 

 TECHNICAL DATA

Equivalents:
PP/L acc. to HRN N.C3.201 
227 IEC 52 acc. to IEC 60227-5  
YML acc. to ÖVE / ÖNORM E 8241

Standards: 
HRN EN 50525-2-11 
EN 50525-2-11 
IEC 60227-5 

Nominal voltage: U0/U = 300/300 V
Test voltage: 2000 V

Temperature range:
Minimum temperature during installation: +5 C
Fixed installed: -15 C to +70 C
At short circuit of max. 5s: 150°C

Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2

Minimal inner bending radius: 7,5xØ cable

CONSTRUCTION DATA
Construction

Outer
diameter

Conductor
resistance
at 20 °C

Cu
weight

Cable
weight

Packing*
mm2 ca. mm Ω/km kg/km ca. kg/km  
2 X 0,75 5,6 26 14,4 48 KOT 50, KOT 100
3 X 0,75 5,9 26 21,6 57 KOT 50, KOT 100
4 X 0,75 6,5 26 28,8 70 KOT 50, KOT 100
5 X 0,75 7,1 26 36 87 KOT 50, KOT 100
 
 
Sheath colour identification

(wh) white
(bk) black
(gy) grey (for YML equivalent only)

* Packing: KOT 50 = coil 50m, KOT 100 = coil 100m, SP = cable on plywood reel

 PDF Download      VDE certificate