Career opportunities

coming soon... 

Contact

Miviko d.o.o.

Rastovaca bb
88240 Posusje
Bosnia i Herzegovina
Tel: +38739852333
Fax: +38739852334
This email address is being protected from spambots. You need JavaScript enabled to view it.

Commercial office
Tel: +38739852340
Fax: +38739852334
Mob: +38763299261
This email address is being protected from spambots. You need JavaScript enabled to view it.

Kontakti

Contact

Ostale informacije

Miviko d.o.o.

Rastovaca bb
88240 Posusje
Bosnia and Herzegovina
Tel: +38739852333
Fax: +38739852334
This email address is being protected from spambots. You need JavaScript enabled to view it.

Sales
Tel: +38739852340
Fax: +38739852334
Mob: +38763299261
This email address is being protected from spambots. You need JavaScript enabled to view it.

FROR

FROR
PVC insulated and sheathed power cable
CEI 20-20

cable conforms to Low voltage directive max. permitted conductor temperature min. installation temperature flame retardant acc. IEC 60332-1
CONSTRUCTION
Conductor    fine wired copper conductor, class 5, acc. to EN 60228

Insulation   PVC compound TI2 acc. to EN 50363-3
Sheath    PVC compound TM2 for flexible cables acc. to EN 50363-4-1

 

APPLICATION

Cables for static use and connections to mobile devices in place with fire risk like fairs, housing, industry and handicraft. Can be laid indoor, in normal or humid environments and temporarily outside. Underground installation is not permitted even if protected.
 

 TECHNICAL DATA

Standards: 
CEI 20-20

Nominal voltage: U0/U = 450/750 V
Test voltage: 2500 V

Temperature range:
Minimum temperature during installation: 0° C
Fixed installed: -30° C to +70° C
At short circuit of max. 5s: 160° C

Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2

Minimal inner bending radius: 4xØ cable

CONSTRUCTION DATA
Construction

Outer
diameter

Conductor
resistance
at 20 °C

Current
carrying
capacity (air)

Current
carrying
capacity (ground)

Cu
weight

Cable
weight

Packing*
mm2 ca. mm Ω/km nom.A nom.A kg/km ca. kg/km  
2 X 1,5 8,1 13,3 17 19,5 28,8 98 KOT 100, SP40 500
2 X 2,5 9,9 7,98 22,5 26 48 150 KOT 100, SP45 500
2 X 4 10,5 4,95 30 35 76,8 190 KOT 100, SP50 500
2 X 6 12,5 3,3 40 46 115,2 260 KOT 100, SP60 500
2 X 10 16,9 1,91 52 63 192 470 KOT 100, SP75 500
3 X 1,5 8,5 13,3 17 19,5 43,2 116 KOT 100, SP40 500
3 X 2,5 10,4 7,98 22,5 26 72 179 KOT 100, SP50 500
3 X 4 11,7 4,95 30 35 115,2 240 KOT 100, SP60 500
3 X 6 13,4 3,3 40 46 172,8 330 KOT 100, SP60 500
3 X 10 17,9 1,91 46 57 288 580 KOT 100, DB09 500
3 X 16 20,7 1,21 62 76 460,8 820 DB10 500
4 X 1,5 9,5 13,3 17 19,5 57,6 147 KOT 100, SP45 500
4 X 2,5 11,4 7,98 22,5 26 96 221 KOT 100, SP50 500
4 X 4 12,7 4,95 30 35 153,6 296 KOT 100, SP60 500
4 X 6 14,4 3,3 40 46 230,4 404 KOT 100, SP70 500
4 X 10 18,4 1,91 52 63 384 676 DB09 500
4 X 16 21,3 1,21 69 85 614,4 978 DB10 500
5 X 1,5 10,3 13,3 17 19,5 72 180 KOT 100, SP50 500
5 X 2,5 12,2 7,98 22,5 26 120 258 KOT 100, SP60 500
5 X 4 14,5 4,95 30 35 192 379 KOT 100, SP70 500
5 X 6 16,0 3,3 40 46 288 501 DB09 500
5 X 10 20,5 1,91 52 63 480 841 DB10 500
5 X 16 23,4 1,21 69 85 768 1190 DB10 500
 
 
Sheath colour identification

(gy) grey

*Packing: KOT 100 = coil 100m, SP = cable on plywood reel, DB = cable on wooden drum

PDF Download     

CYY-F

(N)2XY
XLPE insulated, PVC sheathed power cable
HRN HD 603 S1 - DIN VDE 0276-603 - IEC 60502-1

cable conforms to Low voltage directive max. permitted conductor temperature min. installation temperature flame retardant acc. IEC 60332-1 UV resistant cable cable for direct burial
CONSTRUCTION
Conductor    Cu, class 1 or 2 acc. to EN 60228
a) Class 1:    solid, round (RE)
b) Class 2:    multi wire stranded, round (RM)

Insulation    XLPE-compound DIX 3 acc. to HD 603 S1

Filler    in multi wire cables) extruded elastomer or plastomer compound
Sheath    PVC compound DMV-6 acc. to HD 603 S1
APPLICATION

Distribution and signal power cable for static application in ground, within facilities, in cable canals, in concrete, where heavier mechanical stresses are not expected, and the cable has to be protected against mechanical damages, also in conditions where cables are not exposed to heavier tensile strains. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants where heavier current and thermal loads are expected (operating temperature of conductor up to 90 °C).
 

 TECHNICAL DATA

Equivalents::
XP00 acc. to HRN N.C5 230
Cu/XLPE/PVC acc. to BS 5467

Standards: 
HRN HD 603 S1 
DIN VDE 0276-603
IEC 60502-1

Nominal voltage: U0/U = 0,6/1 kV
Test voltage: 4 kV

Temperature range:
Minimum temperature during installation: -5° C
Fixed installed: -20° C to +90° C
At short circuit of max. 5s: 250° C

Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2

Minimal inner bending radius: 12xØ multi core,
15xØ single core

CONSTRUCTION DATA
Construction

Shape
of the
conductor

Outer
diameter

Conductor
resistance
at 20 °C

Current
carrying
capacity (air)

Current
carrying
capacity (ground)

Cu
weight

Cable
weight

Packing*
mm2   ca. mm Ω/km nom.A nom.A kg/km ca. kg/km  
1 X 10 RE/RM 9,3 1,83 77 89 96 142 SP40 500
1 X 16 RE/RM 10,4 1,15 102 115 153,6 205 SP45 500
1 X 25 RE 12,1 0,727 138 148 240 303 SP50 500
1 X 35 RE 13,2 0,524 170 177 336 394 SP60 500
1 X 50 RE 14,8 0,387 207 209 480 516 SP60 500
2 X 1,5 RE 9,5 12,1 26 37 28,8 126 SP45 500
2 X 2,5 RE 10,2 7,41 36 49 48 157 SP45 500
2 X 4 RE 11,4 4,61 49 64 76,8 200 SP50 500
2 X 6 RE 12,4 3,08 63 79 115,2 253 SP60 500
3 X 1,5 RE 9,9 12,1 24 31 43,2 147 KOT 100, SP45 500
3 X 2,5 RE 10,8 7,41 32 40 72 187 KOT 100, SP50 500
3 X 4 RE 12,0 4,61 42 52 115,2 243 KOT 100, SP60 500
3 X 6 RE 13,1 3,08 53 64 172,8 315 SP60 500
3 X 10 RE/RM 16,3 1,83 74 86 288 495 DB09 500
3 X 16 RE/RM 18,5 1,15 98 112 460,8 712 DB08 500
3 X 25 RE 22,7 0,727 133 145 720 1038 DB09 500
4 X 1,5 RE 11,2 12,1 24 31 57,6 173 KOT 100, SP50 500
4 X 2,5 RE 12,2 7,41 32 40 96 224 KOT 100, SP50 500
4 X 4 RE 13,8 4,61 42 52 153,6 292 KOT 100, SP60 500
4 X 6 RE 15,0 3,08 53 64 230,4 382 DB08 500
4 X 10 RE/RM 18,3 1,83 74 86 384 612 DB08 500
4 X 16 RE/RM 21,0 1,15 98 112 614,4 889 DB09 500
4 X 25 RE 27,3 0,727 133 145 960 1328 DB10 500
5 X 1,5 RE 13,3 12,1 24 31 72 205 KOT 100, SP50 500
5 X 2,5 RE 14,3 7,41 32 40 120 267 KOT 100, SP60 500
5 X 4 RE 16,7 4,61 42 52 192 358 DB08 500
5 X 6 RE 18,1 3,08 53 64 288 471 DB08 500
5 X 10 RE/RM 22,4 1,83 74 86 480 745 DB08 500
5 X 16 RE/RM 25,7 1,15 98 112 768 1066 DB09 500
 
 
Sheath colour identification

(bk) black

* Packing: KOT 100 = coil 100m, SP = cable on plywood reel, DB = cable on wooden drum

 PDF Download      

YSLY

YSLY
PVC insulated and sheathed flex. control cable

cable conforms to Low voltage directive max. permitted conductor temperature min. installation temperature flame retardant acc. IEC 60332-1
CONSTRUCTION
Conductor    bare copper conductor, fine wired stranded, class 5 acc. to EN 60228

Insulation    PVC compound TI2 acc. to EN 50363-3 

Sheath    PVC compound TM2 for flexible cables acc. to EN 50363-4-1

 

APPLICATION

In dry and damp locations for low and medium-level mechanical stress, but not in the open-air. To be used as a termination and connection cable in the control, measuring and signal technology. Suitable as a signal and impulse cable for control and inspection of industrial plants, production lines and machinery.
 

 TECHNICAL DATA

Cable type:
YSLY-JZ cores with black figures,
with green/yellow core
YSLY-OZ cores with black figures,
without green/yellow core
YSLY-JB cores in different colours,
with green/yellow core
YSLY-OB cores in different colours,
without green/yellow core

Nominal voltage: U0/U = 300/500 V
Test voltage: 2000 V

Temperature range:
Minimum temperature during installation: -5°C
Fixed installed: -15°C to +70°C
At short circuit of max. 5s: 160°C

Behaviour in fire:
Flame retardant (self-extinguishing) cable
acc. to EN 60332-1-2

Minimal inner bending radius:
fixed installation 4xØ cable,
moved application 15xØ cable

CONSTRUCTION DATA
Construction

Outer
diameter

Conductor
resistance
at 20 °C

Cu
weight

Cable
weight

Packing*
mm2 ca. mm Ω/km kg/km ca. kg/km  
2 X 0,5 4,8 39 9,6 35 KOT 100, SP40 500
2 X 0,75 5,2 26 14,4 42 KOT 100, SP40 500
2 X 1 5,6 19,5 19,2 52 KOT 100, SP40 500 
2 X 1,5 6,4 13,3 28,8 65 KOT 100, SP40 500
2 X 2,5 7,6 7,98 48 99 KOT 100, SP40 500
3 X 0,5 5,1 39 14,4 41 KOT 100, SP40 500
3 X 0,75 5,5 26 21,6 51 KOT 100, SP40 500
3 X 1 6,1 19,5 28,8 65 KOT 100, SP40 500
3 X 1,5 6,8 13,3 43,2 80 KOT 100, SP40 500
3 X 2,5 8,3 7,98 72 128 KOT 100, SP40 500
3 X 4 10,0 4,95 115,2 169 KOT 100, SP45 500
3 X 6 11,5 3,3 172,8 267 KOT 100, SP60 500
3 X 10 15,0 1,91 288 465 KOT 100, SP70 500
4 X 0,5 5,5 39 19,2 49 KOT 100, SP40 500
4 X 0,75 6,2 26 28,8 63 KOT 100, SP40 500
4 X 1 6,7 19,5 38,4 78 KOT 100, SP40 500
4 X 1,5 7,6 13,3 57,6 102 KOT 100, SP40 500
4 X 2,5 9,0 7,98 96 159 KOT 100, SP45 500
4 X 4 11,0 4,95 153,6 242 KOT 100, SP50 500
4 X 6 13,0 3,3 230,4 340 KOT 100, SP60 500
4 X 10 17,0 1,91 384 577 KOT 100, SP75 500
5 X 0,5 6,2 39 24 60 KOT 100, SP40 500
5 X 0,75 6,7 26 36 78 KOT 100, SP40 500
5 X 1 7,5 19,5 48 95 KOT 100, SP40 500
5 X 1,5 8,3 13,3 72 125 KOT 100, SP40 500
5 X 2,5 10,1 7,98 120 199 KOT 100, SP50 500
5 X 4 12,5 4,95 192 302 KOT 100, SP60 500
5 X 6 14,0 3,3 288 424 KOT 100, SP70 500
5 X 10 18,5 1,91 480 717 KOT 100, DB09 500
6 X 0,75 7,3 26 43,2 85 KOT 100, SP40 500
6 X 1 7,9 19,5 57,6 102 KOT 100, SP40 500
6 X 1,5 8,5 13,3 86,4 129 KOT 100, SP45 500
7 X 0,5 6,7 39 33,6 77 KOT 100, SP40 500
7 X 0,75 7,5 26 50,4 95 KOT 100, SP40 500
7 X 1 8,1 19,5 67,2 120 KOT 100, SP40 500
7 X 1,5 9,2 13,3 100,8 166 KOT 100, SP45 500
7 X 2,5 11,2 7,98 168 258 KOT 100, SP60 500
 
 
Sheath colour identification

(gy) grey

* Packing: KOT 100 = coil 100m, SP = cable on plywood reel, DB = cable on wooden drum

PDF Download        DoP